Chapter 1. General introduction

SCD508 series intelligent temperature controller can be applied in the control and

alarm in range of -200~1750°C. It can used in the controller and alarm of pressure,

discharge, liquid level and humidity etc, parameters when fitted with corresponding

transmitter.

The key features include:

1. Manifold signals including signals of thermocouple, resistance thermometer detector

(RTD), direct voltage, direct current, resistance can be input freely.

2. The input uses digital correction system; there is non-linear correction form of

communal used thermocouple and resistance thermometer detector.

3. Freely changeable with on-off control or PID control with configurable direct reverse

action modes. It has the self-tuning function of PID parameter.

4.Control output supports relay contact switch, solid-state relay (SSR) driving voltage, and

single-phase thyristor zero-crossing trigger signal etc.

5. One way of programmable alarm outputs is provided with a number of alarm modes

including higher -limit, lower limit. In addition, the alarm feature can also be

temporarily disabled when applying the power.

6. Comprehensive self-detection and protection-- In case of error, it provides automatic

 Chapter 2. Type and designation

Chapter 3. Technical Parameters(freely changeable with keypad)

Input type

Code

Measuring range

Input type

Code

Measuring range

Thermocouple

(TC)

K

-50°C~+1350°C

DC voltage

(U)

0-5V

Customized

range within

-1999~+999

S

-50°C~+1750°C

1-5V

E

-50°C~+800°C

J

-50°C~+1000°C

resistance

thermometer

detector

(RTD)

Cu50

-50°C~+150°C

DC current(I)

0-20mA

Pt100

-200°C~+850°C

4-20mA

 

Chapter 4. Shape and Hole cutout dimension

Panel dimension

code

Panel dimension

Case dimension

 

W

H

W

H

D

W

H

A

96

96

91

91

100

92

92

D

72

72

67

67

100

68

68

E

48

96

44

90

100

45

92

F

96

48

90

44

100

92

45

G

48

48

44

44

100

45

45

H

160

80

150

75

100

152

76

S

80

160

75

150

100

76

152

Chapter 5. Instrument wiring

Wiring Diagram, SCD508-A.E.F.H.S series

Chapter 6. Ordering instructionsPlease take care to indicate the model, name, input specifications and orderingquantity in a clear and complete manner upon ordering.For example  SCD508-A110-0~1200°Cshows that it is a digital indicating controller with panel dimension of 96×96mm,PID control relay contact switch output, one absolute value higher limitalarm relay output channel, input signal of K-division TC and measuringrange of 0~1200°C.

 

 

 

 